Effective allergen management starts with a documented risk assessment and combines supplier and raw material control, segregation of ingredients and raw materials in storage and handling, controlled production scheduling (running allergen-free products before allergen-containing ones where possible), hygienic design, dedicated equipment and utensils where appropriate and possible, control of rework, airborne dust and powders, staff training and personal hygiene, and validated cleaning procedures. Attention should be given to product changeovers and shared equipment to prevent allergen residues from reaching subsequent products.
No. Hand sanitizers are designed to inactivate microorganisms, but food allergens are not living organisms, so they cannot be 'killed' and must be physically removed. Most food allergens are proteins, but not all regulated allergens are: sulphites, for example, are non-protein substances that must be declared in the EU, the US and Canada. Hand sanitizer does not reliably remove allergenic residues from hands. Washing thoroughly with soap and water is recommended after handling allergen-containing foods. (Source: Cleaning Methods - FoodAllergy.org)
Cleaning should be designed around the food soil and process conditions, rather than the specific allergen alone. Factors such as soil type, equipment design, cleaning method, chemistry, temperature, mechanical action and contact time should be considered to achieve effective removal. The procedure should be built for the worst case: the most difficult soil (for example baked-on, high-fat, high-protein or sticky residues), the highest allergen concentration and the hardest-to-clean areas such as dead legs, seals, gaskets and conveyor joints. Chemistry should match the soil, for example alkaline detergents for protein and fat soils, and the steps, dosages, times and temperatures should be written down so they can be validated and repeated.
Allergens can remain on surfaces until they are effectively removed. In one study, peanut allergen was still detectable on an uncleaned surface after 110 days, highlighting the importance of effective cleaning rather than relying on allergens to degrade over time. (Source: Persistence of peanut allergen on a table surface - PMC)
It may not always be a formal legal requirement, but you must be able to demonstrate that your cleaning process works. In the EU, Regulation (EC) No 852/2004, as amended by Regulation (EU) 2021/382, requires equipment used for allergenic ingredients to be cleaned and checked at least for visible residues before it is used for foods that do not contain them. In the US, the FSMA preventive controls rule requires allergen and sanitation controls to be verified, although it does not specifically require them to be validated. Customers and GFSI-benchmarked certification schemes, however, generally expect validated allergen cleaning, so it is best to be able to show that cleaning controls allergen carryover.
Validation should demonstrate that the cleaning procedure can consistently reduce allergen residues to an acceptable level under defined operating conditions. The acceptable level is typically defined as below the detection limit of a suitable allergen-specific method, or below an action level derived from reference doses. Validation is normally performed under worst-case conditions and repeated over several cleaning cycles, using a combination of surface swabs, rinse or clean-in-place (CIP) final-rinse water and first-off product samples. Once validated, appropriate monitoring and verification activities should be established to confirm that the procedure is followed correctly and continues to perform as intended, and the procedure should be revalidated whenever products, recipes, equipment, chemistry or the cleaning method change.
You need all three for a complete control programme.
Want to learn more about cleaning validation? Watch our on-demand webinar, When, Why, and How to Validate Cleaning in the Food and Beverage Industry.
The appropriate method depends on whether you are validating or routinely verifying cleaning. Allergen-specific lateral flow tests can support rapid on-site verification, while laboratory methods such as ELISA are commonly used for validation and more quantitative assessment. These methods detect proteins, so non-protein allergens such as sulphites require chemical analytical methods instead.
ATP testing can provide a rapid indication of general cleanliness, but it is not allergen-specific. ATP measures residual organic material, not the allergen itself, and some allergenic residues (for example refined or highly processed ingredients) contain little ATP. It can therefore support routine hygiene monitoring but should not be used alone to demonstrate that a particular allergen has been removed. Some sites use high-sensitivity ATP systems on the principle that removing all visible and organic soil also removes the allergen. This is only defensible where, for that specific product soil and surface, the ATP result has first been correlated with an allergen-specific method during validation.
Where possible, start with dry physical removal methods such as vacuuming (ideally with HEPA-filtered equipment), brushing or scraping rather than introducing water. Avoid compressed air, which spreads allergenic dust to other surfaces and lines, and use dedicated or colour-coded tools to prevent transfer between areas. Where equipment cannot be fully dismantled, a purge or push-through with allergen-free material may be used, but only if it has been validated and the purged material is handled as allergen-containing.
Not necessarily. Heat does not reliably eliminate allergenicity and, for some proteins, processing may alter or even increase allergenic potential. Cleaning chemistry behaves similarly: alkaline detergents can break down protein-based soils and help lift them from surfaces, but partially degraded fragments may still be allergenic and may no longer be recognised by test kits, giving a falsely reassuring result. The primary objective of cleaning should therefore be the effective removal of allergenic food residues, rather than assuming that the allergen has been destroyed or denatured.
Reuse requires careful risk assessment because a used cleaning solution could potentially become a source of allergen recontamination. Whether reuse is appropriate depends on the application, system design and the ability to demonstrate that the reused solution does not introduce an unacceptable cross-contact risk. In CIP systems with recovery tanks, typical controls include using single-use solutions for allergen changeovers, maintaining concentration and temperature within defined limits, finishing with a fresh-water final rinse and including the final rinse water in validation testing.
In January 2025, the FDA's updated food allergen guidance (5th edition) removed coconut from the list of tree nuts it considers major food allergens. Coconut-containing foods therefore no longer need coconut in a 'Contains' statement, although coconut must still be declared in the ingredient list. This applies to the US only.Rules differ by market and change over time, so check each market you sell in.
Only for residual risk that remains after effective controls, based on a documented risk assessment. It should not be used by default or as a substitute for good practice. Under the Codex guidelines on precautionary allergen labelling adopted in July 2026, a 'may contain' statement should be used only when, after appropriate mitigation measures, the risk assessment shows that unintended allergen presence is above an action level derived from reference doses. It is still voluntary in most markets, and the rules vary by country.
No. Declaring intentional allergenic ingredients stays mandatory, and no threshold applies to them. The Codex guidelines (adopted July 2026 as an annex to the General Standard for the Labelling of Prepackaged Foods, CXS 1-1985) only address unintended cross-contact: their reference doses and action levels are used to decide whether a precautionary 'may contain' statement is justified, not whether an ingredient can be left off the label. They are not automatically law, so the legal effect depends on the market.
In many cases, yes. Water can help remove and carry allergen residues away from surfaces, making wet cleaning generally more than dry cleaning for allergen removal. However, in low-moisture environments, the use of water must be carefully controlled to avoid creating additional hygiene risks. In these situations, an appropriate balance between dry and wet cleaning should be established and validated to demonstrate effective allergen control. The choice of cleaning method will also depend on the type of surface, equipment design, and production environment.